What are the requirements and specifications for the installation of fire elevators

Time:2024-06-12   Source:江西天虹机电有限公司   Views:1179

1、 Specification for Fire Elevator Installation Requirements


1. If it is a tower, it needs to be equipped if it exceeds 10 floors.


2. If it exceeds 32 meters, it belongs to Class II and also needs to be equipped.


3. Beyond 32 meters, factories and warehouses need to be equipped.


4. Belonging to a category of public, it needs to be equipped.


5. If it belongs to a unit or corridor, it must be equipped if it exceeds 12 floors.


As long as these 5 conditions are met, fire elevators must be equipped to ensure people's personal safety. When setting up fire stairs, it is necessary to consider the specific situation.






2、 Precautions for Fire Elevators


1. The carrying capacity cannot be less than 800 kilograms. If it is very small, it will be impossible for many people to escape at the same time, so the carrying capacity must be much larger than ordinary ones.


2. It is best to set it next to the exterior wall, and the length should not exceed 30 meters. This can be considered based on specific circumstances. This type of elevator must be easy to use and visible at a glance, and cannot be located in a concealed place.


3. When choosing a fire elevator, be sure to identify a big brand, as the quality of the product will be guaranteed and you can use it with peace of mind. If there is a sudden malfunction at a critical moment, it can be very troublesome and also endanger your personal safety.


4. If you don't know how to install it, it's best to find a professional construction team to help. The staff has rich experience, so they will help install it properly.




Copyright © Jiangxi Tianhong Electromechanical Co., Ltd. Contact person: 19917177918 Ms. Huang landline number: 0797-8220752

QQ:2993817878   Address: No. 19-4 Pingfengling Road, Economic and Technological Development Zone, Ganzhou City, Jiangxi Province Technical Support:江西华邦LOGO白色.png

备案号:赣ICP备18014169号-1

Mobile website

Official WeChat



What are the requirements and specifications for the installation of fire elevators

2024-06-12

1、 Specification for Fire Elevator Installation Requirements


1. If it is a tower, it needs to be equipped if it exceeds 10 floors.


2. If it exceeds 32 meters, it belongs to Class II and also needs to be equipped.


3. Beyond 32 meters, factories and warehouses need to be equipped.


4. Belonging to a category of public, it needs to be equipped.


5. If it belongs to a unit or corridor, it must be equipped if it exceeds 12 floors.


As long as these 5 conditions are met, fire elevators must be equipped to ensure people's personal safety. When setting up fire stairs, it is necessary to consider the specific situation.






2、 Precautions for Fire Elevators


1. The carrying capacity cannot be less than 800 kilograms. If it is very small, it will be impossible for many people to escape at the same time, so the carrying capacity must be much larger than ordinary ones.


2. It is best to set it next to the exterior wall, and the length should not exceed 30 meters. This can be considered based on specific circumstances. This type of elevator must be easy to use and visible at a glance, and cannot be located in a concealed place.


3. When choosing a fire elevator, be sure to identify a big brand, as the quality of the product will be guaranteed and you can use it with peace of mind. If there is a sudden malfunction at a critical moment, it can be very troublesome and also endanger your personal safety.


4. If you don't know how to install it, it's best to find a professional construction team to help. The staff has rich experience, so they will help install it properly.